Pay with and your full purchase price is covered
Number of Functions | 8 |
Repeatability Constant Voltage and Temperature | 0.20000000000000001 |
Functions Available | External control of the start - External control for partial stop - On-delay - Off-delay - Interval, start on opening of external control contact - Repeat cycle, with off period start - Repeat cycle, with on period start - Interval |
Reset Time | 50 |
Output Type | Electromechanical |
Contact Configuration | DPDT |
Timing Range | 0.05 s to 300 h |
Minimum Switching Requirement | 12 V per 10 |
Time Scales | 0.05 to 1sec; 0.15 to 3sec; 0.5 to 10sec; 1.5 to 30sec; 5 to 100sec; 15 to 300sec; 1 to 300min; 1.5 to 30min; 1.5 to 30hr; 15 to 300hr |
Contact Materials | AgNi |
Current Rating | 5 |
Degree of Protection | IP50 (Housing) - IP20 (Terminals) |
Input Voltage Range | 24 - 240 VAC/VDC |
Frequency | 50/60 Hz |
Maximum Consumption AC | 2.0 VA (24 VAC) - 2.5 VA (48 VAC) - 3.2 VA (110 VAC) - 6.0 VA (240 VAC) |
Maximum Consumption DC | 1.0 W (48 VDC) - 3.2 W (110 VDC) - 2.0 W (240 VDC) |
Tightening Torque | 4.5 to 9.9 lb-in |
Indication (LED) | 3 |
Mounting Style | Din Rail |
Weight | 149.69999999999999 |
Ambient Air Temperature around the Device - Operation | -20 to 60 |
Approvals | GL - CSA - CE - RoHS - UL |
Ambient Air Temperature around the Device - Storage | -40 to 85 |
Electrical Life (UL508) Operations at Rated Current (Resistive) | 100,000 operations |
Mechanical Life Unpowered | 20,000,000 operations |
Vibration Resistance - Operational | A=0.35 mm |
Shock Resistance | 15 gn - 11 ms |
Features | |
|
|
General | |
Style | ALCUL Three-Conductor, Four-Hole Mount |
Material | Aluminum |
Plating | Tin-Plated |
Conductor Range (AL or CU) Maximum | 1000 kcmil |
Conductor Range (AL or CU) Minimum | 500 kcmil |
Dimension Information | |
Length (inches) | 6 3/16 |
Width (inches) | 4 3/4 |
Height (inches) | 1 7/8 |
D (inches) | 5/8 |
E (inches) | 1/2 |
F (inches) | 9/16 |
G (inches) | 3 7/16 |
I (inches) | 1 41/64 |
AMR Electric is owned and operated by Richard C. Miller (NJ Lic & Bus Pmt #5586) and is a full service electrical contractor serving all of Camden County NJ for both residential and commercial customers. Owner is fully insured and bonded and has 39+ yrs in the electrical industry and has run a business since 1979. Some of the services offered but not limited to are: Electrical service upgrade, air conditioner and appliance hookups, custom lighting, receptacles added, warehouse and office wiring, ballast changes, rewiring, addition wiring, troubleshooting, and security lighting. Free estimates available upon request. Call at 856-701-6772 or e-mail at amrelectric@earthlink.net the next time you need a quality electrical contractor.
Electrical contractors are frequently cited by regulatory agencies such as OSHA and Cal OSHA for not having programatical safety measures in place. If you need a safety manual that is specifically designed to meet regulatory requirements and those of the modern day electrical contractor, we have one. You can instantly download this electrical safety manual at this website. You can also contact me if you have any safety compliance questions as I deal with compliance each and every week.
Click >>>
Subscribe to
Our Store
Newsletter <<<
for New Product info & Specials
Terms of Use